Fiber Distributed Data Interface (FDDI)
The Fiber Distributed Data Interface (FDDI) specifies a 100-Mbps
token-passing, dual-ring LAN using fiber-optic cable. FDDI is frequently
used as high-speed backbone technology because of its support for high
bandwidth and greater distances than copper.
FDDI uses dual-ring architecture with traffic on each ring flowing in
opposite directions (called counter-rotating). The dual rings consist of
a primary and a secondary ring. During normal operation, the primary
ring is used for data transmission, and the secondary ring remains idle. the primary
purpose of the dual rings is to provide superior reliability and
robustness.
FDDI Transmission Media
FDDI uses optical fiber as the primary transmission medium, but it
also can run over copper cabling. FDDI over copper
is referred to as Copper-Distributed Data Interface (CDDI). Optical
fiber has several advantages over copper media. In particular, security,
reliability, and performance all are enhanced with optical fiber media
because fiber does not emit electrical signals. A physical medium that
does emit electrical signals (copper) can be tapped and therefore would
permit unauthorized access to the data that is transiting the medium. In
addition, fiber is immune to electrical interference from radio
frequency interference (RFI) and electromagnetic interference (EMI).
Fiber historically has supported much higher bandwidth (throughput
potential) than copper, although recent technological advances have made
copper capable of transmitting at 100 Mbps. Finally, FDDI allows 2 km
between stations using multimode fiber, and even longer distances using a
single mode.
FDDI defines two types of optical fiber: single-mode and
multimode. A mode is a ray of light that enters the fiber at a
particular angle. Multimode fiber uses LED as the light-generating
device, while single-mode fiber generally uses lasers.
Multimode fiber allows multiple modes of light to propagate
through the fiber. Because these modes of light enter the fiber at
different angles, they will arrive at the end of the fiber at different
times. This characteristic is known as modal dispersion. Modal
dispersion limits the bandwidth and distances that can be accomplished
using multimode fibers. For this reason, multimode fiber is generally
used for connectivity within a building or a relatively geographically
contained environment.
Single-mode fiber allows only one mode of light to propagate
through the fiber. Because only a single mode of light is used, modal
dispersion is not present with single-mode fiber. Therefore, single-mode
fiber is capable of delivering considerably higher performance
connectivity over much larger distances, which is why it generally is
used for connectivity between buildings and within environments that are
more geographically dispersed.
FDDI Specifications
FDDI specifies the physical and media-access portions of the OSI
reference model. FDDI is not actually a single specification, but it is a
collection of four separate specifications, each with a specific
function. Combined, these specifications have the capability to provide
high-speed connectivity between upper-layer protocols such as TCP/IP and
IPX, and media such as fiber-optic cabling.
FDDI's four specifications are the Media Access Control (MAC),
Physical Layer Protocol (PHY), Physical-Medium Dependent (PMD), and
Station Management (SMT) specifications. The MAC specification defines
how the medium is accessed, including frame format, token handling,
addressing, algorithms for calculating cyclic redundancy check (CRC)
value, and error-recovery mechanisms. The PHY specification defines data
encoding/decoding procedures, clocking requirements, and framing, among
other functions. The PMD specification defines the characteristics of
the transmission medium, including fiber-optic links, power levels,
bit-error rates, optical components, and connectors. The SMT
specification defines FDDI station configuration, ring configuration,
and ring control features, including station insertion and removal,
initialization, fault isolation and recovery, scheduling, and statistics
collection.
FDDI Station-Attachment Types
One of the unique characteristics of FDDI is that multiple ways
actually exist by which to connect FDDI devices. FDDI defines four types
of devices: single-attachment station (SAS), dual-attachment station
(DAS), single-attached concentrator (SAC), and dual-attached
concentrator (DAC).
An SAS attaches to only one ring (the primary) through a
concentrator. One of the primary advantages of connecting devices with
SAS attachments is that the devices will not have any effect on the FDDI
ring if they are disconnected or powered off..
Each FDDI DAS has two ports, designated A and B. These ports
connect the DAS to the dual FDDI ring. Therefore, each port provides a
connection for both the primary and the secondary rings. As you will see
in the next section, devices using DAS connections will affect the
rings if they are disconnected or powered off.
An FDDI concentrator (also called a dual-attachment concentrator [DAC])
is the building block of an FDDI network. It attaches directly to both
the primary and secondary rings and ensures that the failure or
power-down of any SAS does not bring down the ring. This is particularly
useful when PCs, or similar devices that are frequently powered on and
off, connect to the ring.
SASs connected to a concentrator.
FDDI Fault Tolerance
FDDI provides a number of fault-tolerant features. In particular,
FDDI's dual-ring environment, the implementation of the optical bypass
switch, and dual-homing support make FDDI a resilient media technology.
Dual Ring
FDDI's primary fault-tolerant feature is the dual ring. If a station
on the dual ring fails or is powered down, or if the cable is damaged,
the dual ring is automatically wrapped (doubled back onto itself) into a
single ring. When the ring is wrapped, the dual-ring topology becomes a
single-ring topology. Data continues to be transmitted on the FDDI ring
without performance impact during the wrap condition.
When a single station fails, as shown in Figure 8-6, devices on
either side of the failed (or powered-down) station wrap, forming a
single ring. Network operation continues for the remaining stations on
the ring. When a cable failure occurs, as shown in the above figure,
devices on either side of the cable fault wrap. Network operation
continues for all stations.
It should be noted that FDDI truly provides fault tolerance
against a single failure only. When two or more failures occur, the FDDI
ring segments into two or more independent rings that are incapable of
communicating with each other.
Dual-fiber ring: (a) normal operation; (b) failure of the primary ring.Dual Homing
Critical devices, such as routers or mainframe hosts, can use a
fault-tolerant technique called dual homing to provide additional
redundancy and to help guarantee operation. In dual-homing situations,
the critical device is attached to two concentrators.
One pair of concentrator links is declared the active link; the other
pair is declared passive. The passive link stays in backup mode until
the primary link (or the concentrator to which it is attached) is
determined to have failed. When this occurs, the passive link
automatically activates.
FDDI Frame Fields
The following descriptions summarize the FDDI data frame and token fields illustrated in the above figure.- Preamble - Gives a unique sequence that prepares each station for an upcoming frame.
- Start delimiter - Indicates the beginning of a frame by employing a signaling pattern that differentiates it from the rest of the frame.
- Frame control - Indicates the size of the address fields and whether the frame contains asynchronous or synchronous data, among other control information.
- Destination address - Contains a unicast (singular), multicast (group), or broadcast (every station) address. As with Ethernet and Token Ring addresses, FDDI destination addresses are 6 bytes long.
- Source address - Identifies the single station that sent the frame. As with Ethernet and Token Ring addresses, FDDI source addresses are 6 bytes long.
- Data - Contains either information destined for an upper-layer protocol or control information.
- Frame check sequence (FCS) - Is filed by the source station with a calculated cyclic redundancy check value dependent on frame contents (as with Token Ring and Ethernet). The destination address recalculates the value to determine whether the frame was damaged in transit. If so, the frame is discarded.
- End delimiter - Contains unique symbols; cannot be data symbols that indicate the end of the frame.
- Frame status - Allows the source station to determine whether an error occurred; identifies whether the frame was recognized and copied by a receiving station.